J. pediatr. (Rio J.) ; 82(5): 359-364, Sept.-Oct. 2006. ilus, tab
Article in Portuguese, English | LILACS | ID: lil-438353

ABSTRACT

OBJETIVO: Avaliar o pico de pressão inspiratória e a freqüência ventilatória obtidos por médicos quando da utilização de balão auto-inflável neonatal em modelo de pulmão. MÉTODOS: Quinze médicos ventilaram simuladores de pulmão de recém-nascidos a termo e pré-termo, sendo os desfechos captados através de um monitor de ventilação. RESULTADOS: As medianas dos picos de pressão foram 23 (intervalo interquartil, 15-47) e 26 (intervalo interquartil, 14-51) cmH2O, sendo menor que 20 em 41,2 e 35,8 por cento das vezes; maior que 40 em 29,7 e 33,6 por cento das vezes e entre 27 e 33 cmH2O em 8,2 e 6,5 por cento das vezes, para o pulmão de termo e de pré-termo, respectivamente. As medianas das freqüências ventilatórias foram de 45 (intervalo interquartil, 36-57) e 48 (intervalo interquartil, 39-55,5) ciclos por minuto, sendo menor que 30 em 9,3 e 6,7 por cento das vezes e maior que 60 em 12 e 13,3 por cento das vezes, respectivamente, para o pulmão de termo e de pré-termo. As diferenças nas medianas não foram estatisticamente significantes. CONCLUSÃO: A ventilação utilizando o balão auto-inflável promoveu adequação para a freqüência ventilatória em aproximadamente 80 por cento das vezes, e os médicos não conseguiram promover ventilação com mínima variabilidade na pressão, alcançando níveis diferentes daqueles definidos no curso de reanimação neonatal em 70 por cento das vezes. Essa situação independeu da ventilação do pulmão-teste análogo ao sistema respiratório de recém-nascidos a termo ou pré-termo.


OBJECTIVE: To evaluate the peak inspiratory pressure and ventilation rate achieved by physicians when using a neonatal self-inflating bag on a lung model. METHODS: Fifteen physicians ventilated full term and preterm infant lung simulators while the outcomes were captured by a ventilation monitor. RESULTS: Median peak pressures in cmH2O for full term and preterm lungs were 23 (interquartile range: 15-47) and 26 (interquartile range: 14-51), being less than 20 in 41.2 and 35.8 percent of the pressure curves analyzed, more than 40 in 29.7 and 33.6 percent, and between 27 and 33 cmH2O in 8.2 and 6.5 percent of the curves, respectively. Median ventilation rates were 45 (interquartile range: 36-57) and 48 (interquartile range: 39-55.5) cycles per minute, being more than 30 in 9.3 and 6.7 percent of pressure curves and more than 60 in 12 and 13.3 percent of pressure curves, for the full term and preterm lungs, respectively. The differences between these medians were not statistically significant. CONCLUSIONS: Ventilation rates achieved with the self-inflating bag were adequate in approximately 80 percent of pressure curves analyzed, but the physicians were unable to provide ventilation with minimal pressure variation, producing pressures that diverged from those defined by the neonatal resuscitation training course in 70 percent of the curves. This was irrespective of whether they were ventilating the lung model analogous to preterm or full term infant lungs.


Subject(s)
Humans , Infant, Newborn , Cardiopulmonary Resuscitation/instrumentation , Heart Rate/physiology , Inspiratory Capacity/physiology , Respiration, Artificial/instrumentation , Ventilators, Mechanical/standards , Cardiopulmonary Resuscitation/methods , Infant, Premature , Lung/physiology , Neonatology , Professional Practice , Respiration, Artificial/methods , Respiratory Function Tests/methods
SELECTION OF CITATIONS
SEARCH DETAIL